MultiCrafTest Pumps, Piping and Combustion

Pumps, piping and combustion for the Ramsay MultiCrafTest: head and pressure, pump power, affinity laws, NPSH and cavitation, water hammer, steam traps and burners.

Practicing for the Ramsay MultiCrafTest? Take the free practice test: 14 questions, no account needed.

Ramsay's MultiCrafTest product page lists Pumps, Piping, and Combustion as one of its seven categories. In your ExamVanta results, this area is called Pumps, piping and combustion. Ramsay doesn't publish how many of the 60 questions come from each area.

This guide goes deeper than the mechanical maintenance overview. It covers the pump formulas a journey-level technician uses, why pumps cavitate and how to prove it, how piping and steam systems fail, and the basics of safe combustion. The five worked examples are original, with the arithmetic shown.

The pump relations to know

Quantity Relation
Pressure from head psi = feet of head × specific gravity ÷ 2.31
Water horsepower gal/min × feet of head × specific gravity ÷ 3,960
Brake (shaft) horsepower water horsepower ÷ pump efficiency
Pipe velocity ft/s = 0.4085 × gal/min ÷ (inside diameter in inches)²
Affinity laws, speed change flow follows speed, head follows speed², power follows speed³
Affinity laws, small impeller trim flow follows diameter, head follows diameter², power follows diameter³
Pumps in parallel flows add at the same head
Pumps in series heads add at the same flow

Pump curves are drawn in feet of head because a centrifugal pump lifts any thin liquid to the same height. The pressure that height makes, and the power it takes, depend on the liquid's specific gravity.

Worked examples

1. Same head, different pressure. A centrifugal pump develops 150 ft of head.

  • On water: 150 × 1.0 ÷ 2.31 ≈ 64.9 psi.
  • On a liquid with a specific gravity of 0.85: 150 × 0.85 ÷ 2.31 ≈ 55.2 psi.

The pump is fine. A lower gauge reading on a lighter liquid isn't a fault.

2. Pump power, and what a heavier liquid does to it. A pump moves 250 gal/min of water against 140 ft of head at 70% efficiency.

  • Water horsepower = 250 × 140 × 1.0 ÷ 3,960 ≈ 8.84 hp.
  • Brake horsepower = 8.84 ÷ 0.70 ≈ 12.6 hp.
  • Switch to a brine with a specific gravity of 1.2: 12.6 × 1.2 ≈ 15.2 hp. A 15-hp motor that was fine on water is now running above its nameplate rating.

3. Slowing a pump with a VFD. A pump on a closed circulating loop, with no static lift, gives 360 gal/min at 1,780 rpm and draws 25 hp. You need 300 gal/min.

  • Speed = 1,780 × 300 ÷ 360 ≈ 1,483 rpm.
  • Head falls to (300 ÷ 360)² ≈ 0.69 of what it was.
  • Power = 25 × (300 ÷ 360)³ = 25 × 0.579 ≈ 14.5 hp.

Throttling a valve to get the same flow would leave the pump at full speed and burn the difference across the valve. One caution: the affinity laws describe the pump, not the system. On a system with a large static lift, flow falls faster than speed, and you need the pump and system curves to predict it.

4. NPSH: why hot liquid cavitates. A pump draws from an open tank at sea level. The liquid surface is 8 ft below the pump, the suction line loses 3 ft to friction, and the pump needs 12 ft of NPSH at its duty point. NPSH available = atmospheric head − suction lift − friction loss − vapor pressure head.

  • Cold water at 60°F (vapor pressure about 0.26 psia): atmospheric head = 14.7 × 2.31 ≈ 34.0 ft, vapor head = 0.26 × 2.31 ≈ 0.6 ft. NPSH available = 34.0 − 8 − 3 − 0.6 ≈ 22.4 ft, a margin of about 10 ft over the 12 ft required.
  • Hot water at 180°F (vapor pressure about 7.5 psia, specific gravity about 0.97): atmospheric head = 14.7 × 2.31 ÷ 0.97 ≈ 35.0 ft, vapor head = 7.5 × 2.31 ÷ 0.97 ≈ 17.9 ft. NPSH available = 35.0 − 8 − 3 − 17.9 ≈ 6.1 ft, well short of 12 ft. It cavitates.

The fixes follow from the formula: flood the suction by raising the tank or lowering the pump, cut suction losses (a clean strainer, a larger or shorter suction line, fewer fittings), cool the liquid, or choose a pump that needs less NPSH. Never control a centrifugal pump's flow by throttling its suction valve; that lowers NPSH available.

5. Water hammer from a fast-closing valve. Water flows at 250 gal/min in 4-in Schedule 40 steel pipe, inside diameter 4.026 in.

  • Velocity = 0.4085 × 250 ÷ 4.026² = 102.1 ÷ 16.21 ≈ 6.3 ft/s.
  • Stopping it instantly raises pressure by about density × wave speed × velocity. With water at 1.94 slugs/ft³ and a wave speed of about 4,000 ft/s in steel pipe: 1.94 × 4,000 × 6.3 ÷ 144 ≈ 340 psi, on top of the operating pressure.
  • The pressure wave takes 2 × length ÷ wave speed to travel to the far end and back. On a 600-ft line that's 2 × 600 ÷ 4,000 = 0.3 s. A valve closed faster than that gives the full surge; closing it over many times that interval cuts the surge sharply.

Check the rule of thumb: 1.94 × 4,000 ÷ 144 ≈ 54 psi for each 1 ft/s stopped.

Pump troubleshooting

Symptom Likely causes to check
No flow at start-up not primed or air-bound, suction valve closed, wrong rotation
Gravel-like noise, falling flow cavitation: low NPSH available, often a clogged strainer or hot liquid
Flow and head slowly falling worn wear rings or impeller, partly blocked impeller, air leaking into a suction line under lift
Low head right after motor work wrong rotation: a centrifugal pump turning backward still pumps, but poorly
Motor overloading running far out on the curve at high flow, or a heavier or thicker liquid
Pump hot, little flow running near shutoff with the discharge closed; the trapped liquid heats
Seal leaking or failed early running dry, misalignment, pipe strain, or a blocked seal flush

Positive displacement pumps behave differently. They deliver nearly the same flow whatever the pressure, so a closed discharge valve makes pressure climb until something breaks. They need a relief valve, and you never start one against a closed discharge.

Packing and seals. Packing is meant to leak slightly, to cool and lubricate itself. Tightening it until it stops dripping burns the packing and scores the shaft sleeve. A mechanical seal must never run dry.

Support piping so that the pump never carries its weight. Pipe strain pulls the pump out of alignment and shortens seal and bearing life.

Piping, valves and steam

  • Gate valves are for fully open or fully closed service, not throttling. Globe valves throttle. Check valves stop backflow. Ball and butterfly valves are quarter-turn. Close any valve on a long liquid line slowly.
  • Steam traps discharge condensate and air while holding back steam. A trap that fails open blows live steam into the return and wastes energy. One that fails closed backs condensate up, so the equipment runs cold and water hammer becomes likely. Test traps by comparing temperatures across them, with an ultrasonic tester, or at a sight glass.
  • Water hammer in steam lines comes from condensate pooling at low points, where steam picks it up as a slug. Pitch lines toward drip legs with traps, and warm up a cold main slowly with its drains open.
  • Thermal expansion. Steel pipe grows about 3/4 in per 100 ft for every 100°F rise. Hot lines need expansion loops or joints, anchors and guides.
  • Strainers need a pressure gauge on each side, or a differential gauge. A rising difference means the basket is filling.

Combustion basics

  • Too little air gives carbon monoxide, soot, and on a gas burner a lazy yellow flame. Too much air carries heat up the stack and wastes fuel.
  • A common estimate of excess air from the flue gas oxygen reading is excess air % ≈ O2 ÷ (20.9 − O2) × 100. For example, 3% oxygen gives 3 ÷ 17.9 × 100 ≈ 17% excess air. Tune to the burner maker's targets.
  • The burner management system purges the furnace before ignition, proves the pilot and main flame with a scanner or flame rod, and closes the safety shutoff valves if the flame fails. After a flame failure, the furnace is purged again before any relight.
  • Keep combustion air openings clear, and treat any sign of flue gas spilling into a room as a carbon monoxide hazard.

Safety rules that decide answers

  • Isolate both the driver and the liquid. Lock out the motor, close and lock the suction and discharge valves, then drain and vent the casing and confirm it's at zero pressure and a safe temperature before you open it. Hazardous lines may need double block and bleed.
  • Never open a strainer, trap or flange under pressure. Let steam lines cool and drain first.
  • Never bypass a flame safeguard, low-water cutoff or relief valve, and never relight a burner without the purge.
  • Treat tanks and vessels as confined spaces, and follow your site's entry permit rules before going in.

How to practice this area

  • Convert head and pressure both ways until it's automatic, using 2.31 and the specific gravity.
  • Write NPSH available as a sum of terms, and ask which term the question changed.
  • For any troubleshooting stem, decide first whether it's a suction problem, a pump problem or a system problem.

Cavitation in hydraulic pumps is covered in the hydraulics and pneumatics guide. Our other mechanical area guides cover welding and rigging and power transmission, and the study plan shows how to fit them together.

Practice that matches the test

Our Ramsay MultiCrafTest practice tests give you 20 full tests of 60 original questions, mixed across the seven craft areas, with a score for pumps, piping and combustion and every other area, and a worked explanation for every question. Start with the free practice test.

Free to share: you may copy and share this guide unchanged, for non-commercial purposes such as teaching and study, if you credit ExamVanta and link to this page. It's licensed under CC BY-NC-ND 4.0. Material from other sources quoted or shown in it, such as official text or chart excerpts, keeps its own terms.